Pdr58; Pdr59 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

PDR58

arg1 is incompatible.
Message
Arguments
Detailed
A user attempted to replace a disk with another disk that is using an incompatible technology.
Description
For example, replaced one side of a mirror with a SAS disk when the other side of the mirror is
using SATA technology.
Recommended
Refer to the hardware documentation for information on replacing disks.
Response Action
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 2 (Warning)
Trap/EventID
4346
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

PDR59

Message
A bad disk block was reassigned on
Arguments
Detailed
The disk has a bad block. Data was remapped to another disk block. No data loss has
Description
occurred.
Recommended
Monitor the disk for other messages or indications of poor health.
Response Action
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 3 (Informational)
Trap/EventID
4347
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
arg1 = PD Name
Email
LC Log
Alert
TRUE
TRUE
arg1 = physical disk
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
arg1 .
Reset
FALSE
457

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents