CMC8534

Message
Unable to turn on the server
cap value.
Arguments
Detailed
Unable to turn on the server specified in the message, because the available power is lesser
Description
than the requested power.
Recommended
In the CMC Web interface, verify the available power and server power requirements. If
Response Action
sufficient power is available, retry the operation. Otherwise, increase the power cap value.
Category
System Health
SubCategory
CMC = Chassis Management Controller
Severity
Severity 2 (Warning)
Trap/EventID
2546
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

CMC8535

Message
Unable to turn on High Power Management for the server
Arguments
Detailed
Unable to turn on the server specified in the message because of an internal CMC error.
Description
Recommended
Reboot CMC and retry the operation. If the issue persists, reseat the server and retry the
Response Action
operation.
Category
Audit
SubCategory
CMC = Chassis Management Controller
Severity
Severity 1 (Critical)
Trap/EventID
8689
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
arg1 because the power requirement request exceeds the power
arg1 = slot number
Email
LC Log
Alert
TRUE
TRUE
arg1 = slot number
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
arg1
Reset
FALSE