Vlt0103; Vlt0104 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

VLT0103

Message
Processor module
Arguments
Detailed
System hardware detected an over voltage or under voltage condition. If multiple voltage
Description
exceptions occur consecutively the system may power down in failsafe mode.
Recommended
1) Review system logs for power supply exceptions. 2) Remove the processor module. Inspect
Response Action
processor socket for bent pins. 3) If the problem persists, contact technical support. Refer to
the product documentation to choose a convenient contact method.
Category
System Health
SubCategory
VLT = Voltage
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
Processor module <name> voltage is outside of range . Contact support
Initial Default.
FALSE
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

VLT0104

Message
Processor module
Arguments
Detailed
System hardware detected an over voltage or under voltage condition. If multiple voltage
Description
exceptions occur consecutively the system may power down in failsafe mode.
Recommended
1) Review system logs for power supply exceptions. 2) Remove the processor module. Inspect
Response Action
processor socket for bent pins. 3) If the problem persists, contact technical support. Refer to
the product documentation to choose a convenient contact method.
Category
System Health
SubCategory
VLT = Voltage
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
Email
LC Log
Alert
FALSE
FALSE
arg1 voltage is greater than the upper critical threshold.
arg1 = name
Email
LC Log
Alert
FALSE
FALSE
arg1 voltage is outside of range.
arg1 = name
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
Reset
FALSE
Reset