Severity
Severity 2 (Warning)
Trap/EventID
4354
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

VDR55

arg1 initialization has failed.
Message
Arguments
Detailed
The controller cannot communicate with attached devices. A disk may be removed or contain
Description
errors. Cables may also be loose or defective.
Recommended
Verify the health of attached devices. Review the Alert Log for significant events. Make sure
Response Action
the cables are attached securely. See the Cables Attached Correctly section for more
information on checking the cables.
Category
Storage
SubCategory
VDR = Virtual Disk
Severity
Severity 1 (Critical)
Trap/EventID
4353
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

VDR56

Message
Redundancy of
Arguments
Detailed
This message occurs when a physical disk in the disk group was removed or when a physical
Description
disk included in a redundant virtual disk fails. Because the virtual disk is redundant (uses
mirrored or parity information) and only one physical disk has failed, the virtual disk can be
rebuilt. Typically, the virtual disk (E.g. RAID 6) has multiple redundant disks and there is a
problem with one of them.
886
Email
LC Log
Alert
TRUE
TRUE
arg1 = VD Name
Email
LC Log
Alert
TRUE
TRUE
arg1 has been degraded.
arg1 = virtual disk
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
Reset
FALSE
Reset
FALSE