Stor Event Messages; Stor1; Stor2 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

STOR Event Messages

STOR1

Message
A device
Arguments
Detailed
The controller cannot communicate with a device. The state of the device cannot be
Description
determined. There may be a bad or loose cable, or a missing device, or a problem with the
driver or firmware.
Recommended
See the storage hardware documentation for information on checking the cables. Check for
Response Action
problems with any enclosures attached to the system. Verify that the controller has a
supported version of the driver and firmware. Rebooting the system may resolve this problem.
Category
Storage
SubCategory
STOR = Storage
Severity
Severity 2 (Warning)
Trap/EventID
4178
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

STOR2

Message
SCSI sense data
Arguments
Detailed
A SCSI device experienced an error, but may have recovered.
Description
Recommended
No response action is required.
Response Action
Category
Storage
SubCategory
STOR = Storage
arg1 is in an unknown state.
arg1 = device name
Email
LC Log
Alert
TRUE
TRUE
arg1 .
arg1 = args
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
39
Reset
FALSE
713

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents