Pdr20; Pdr21 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

PDR20

Message
SMART configuration change for
Arguments
Detailed
A disk has received a SMART alert (predictive failure) after a configuration change. The disk is
Description
likely to fail in the near future.
Recommended
Replace the disk that has received the SMART alert. If the physical disk is a member of a non-
Response Action
redundant virtual disk, then back up the data before replacing the disk. Removing a physical
disk that is included in a non-redundant virtual disk will cause the virtual disk to fail and may
cause data loss.
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 1 (Critical)
Trap/EventID
4345
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

PDR21

Message
SMART warning for
Arguments
Detailed
A disk has received a SMART alert (predictive failure). The disk is likely to fail in the near
Description
future.
Recommended
Replace the disk that has received the SMART alert. If the physical disk is a member of a non-
Response Action
redundant virtual disk, then back up the data before replacing the disk. Removing a physical
disk that is included in a non-redundant virtual disk will cause the virtual disk to fail and may
cause data loss.
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 2 (Warning)
Email
LC Log
Alert
TRUE
TRUE
arg1 = PD Name
Email
LC Log
Alert
TRUE
TRUE
arg1
arg1 = PD Name
LCD
Power Off Power
TRUE
FALSE
arg1 .
LCD
Power Off Power
TRUE
FALSE
Reset
Cycle
FALSE
FALSE
Reset
Cycle
FALSE
FALSE