Alert
FALSE
FALSE
FALSE

PST0134

Message
Interrupt controller failed.
Detailed
System BIOS detected a failure with the interrupt controller during system POST. This
Description
exception occurred early in system power on, thus the system may not display video. (BIOS
POST Exception code 86)
Recommended
Remove and reapply input power. If the problem persists, contact technical support. Refer to
Response Action
the product documentation to choose a convenient contact method.
Category
System Health
SubCategory
PST = BIOS POST
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
Interrupt controller failed. Power cycle system
Initial Default.
FALSE
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

PST0135

Message
Timer refresh failed.
Detailed
System BIOS detected a timer refresh failure during system POST. This exception occurred
Description
early in system power on, thus the system may not display video. (BIOS POST Exception code
87).
Recommended
Remove and reapply input power. If the problem persists, contact technical support. Refer to
Response Action
the product documentation to choose a convenient contact method.
Category
System Health
SubCategory
PST = BIOS POST
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
Timer refresh failed. Power cycle system
Initial Default.
FALSE
500
Email
LC Log
LCD
Alert
FALSE
FALSE
FALSE
Email
LC Log
LCD
Alert
FALSE
FALSE
FALSE
Power Off Power
Reset
Cycle
FALSE
FALSE
FALSE
Power Off Power
Reset
Cycle
FALSE
FALSE
FALSE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents