Initial Default.
SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

CMC8514

Message
Fabric mismatch is detected in the I/O Module
Arguments
Detailed
This error may occur due to any of the following conditons 1) Invalid I/O Module and mezzanine
Description
card configuration, where a newly installed I/O Modules fabric type and the resident
mezzanine cards fabric types do not match or are incompatible. 2) Invalid I/O Module and I/O
Module configuration, where a newly installed I/O Module has a different or incompatible
fabric type from an I/O Module already installed in the fabric.
Recommended
Refer to Chassis Management Controller Users Guide for additional information.
Response Action
Category
System Health
SubCategory
CMC = Chassis Management Controller
Severity
Severity 1 (Critical)
Trap/EventID
2545
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

CMC8516

Message
The I/O Module
Arguments
Detailed
The I/O module may have taken more time to boot than was expected or the I/O module did not
Description
boot.
Recommended
Verify the I/O Module is turned on using CMC Web Interface or RACADM CLI and retry the
Response Action
operation. Otherwise, reinsert the I/O Module and retry the operation. If the problem persists,
contact technical support.
Category
System Health
112
Email
LC Log
Alert
TRUE
TRUE
arg1 = iom slot name
Email
LC Log
Alert
TRUE
TRUE
arg1 did not boot within the expected time.
arg1 = iom slot name
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
arg1 .
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
Reset
FALSE
Reset
FALSE