Detailed
The only physical disk available to be assigned as a hot spare is using SAS technology. The
Description
physical disks in the virtual disk are using SATA technology. Because of this difference in
technology, the hot spare cannot rebuild data if one of the physical disks in the virtual disk
fails.
Recommended
Add a SATA disk that is large enough to be used as the hot spare and assign the new disk as a
Response Action
hot spare.
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 2 (Warning)
Trap/EventID
4346
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE
PDR37
Message
The
Arguments
Detailed
The physical device may not have a supported version of the firmware or the physical device
Description
may not be supported.
Recommended
If the physical device is supported, then update the firmware to a supported version. If the
Response Action
physical device is not supported, then replace the physical device with one that is supported.
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 2 (Warning)
Trap/EventID
4346
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE
PDR38
Message
A clear operation started on
446
Email
LC Log
Alert
TRUE
TRUE
arg1 is not supported.
arg1 = physical device
•
Email
LC Log
Alert
TRUE
TRUE
arg1 .
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
Reset
FALSE
Reset
FALSE