Pdr44; Pdr46 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

PDR44

Message
The clear operation on
Arguments
Detailed
A Clear task was being performed on a physical disk but the task was interrupted and did not
Description
complete successfully. The controller may have lost communication with the disk, the disk was
removed, or the cables may be loose or defective.
Recommended
Verify that the disk is present and not in a Failed state. Make sure the cables are attached
Response Action
securely. See the storage hardware documentation for more information on checking the
cables. Restart the Clear task.
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 1 (Critical)
Trap/EventID
4345
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

PDR46

Message
Patrol Read found an uncorrectable media error on
Arguments
Detailed
The Patrol Read task has encountered an error that cannot be corrected. There may be a bad
Description
disk block that cannot be remapped.
Recommended
Backup your data from the disk. Start disk initialization and wait for it to complete, then restore
Response Action
the data from the backup to the disk.
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 1 (Critical)
450
Email
LC Log
Alert
TRUE
TRUE
arg1 failed.
arg1 = physical disk
Email
LC Log
Alert
TRUE
TRUE
arg1 = physical disk
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
arg1 .
Reset
FALSE
Reset
FALSE

Hide quick links: