Arguments
Detailed
For failover to occur, the standby CMC needs to be present, at the same version as the primary
Description
and healthy. During failover, the active CMC resets and the standby CMC becomes active. This
message is logged when the standby CMC is absent, unhealthy or at a different firmware
version.
Recommended
Check the status of the standby CMC and make sure the firmware version matches the primary
Response Action
CMC. Then reseat the CMC and retry the operation. If the issue persists, contact your service
provider.
Category
Audit
SubCategory
RDU = Redundancy
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE
RDU8511
Message
Unable to failover, CMC
Arguments
Detailed
For failover, the standby CMC needs to be present, at the same firmware version as the primary
Description
CMC and healthy. During failover, the active CMC resets and the standby CMC becomes active.
This message is logged when the standby CMC does not meet this criteria
Recommended
Check the status of the standby CMC and make sure the firmware version matches the primary
Response Action
CMC. Then reseat the CMC and retry the operation. If the issue persists, contact your service
provider.
Category
Audit
SubCategory
RDU = Redundancy
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
arg1 = slot number
•
Email
LC Log
Alert
FALSE
TRUE
arg1 in unknown state.
•
arg1 = slot number
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
Reset
FALSE
629