Rdu8502; Rdu8506 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

RDU8502

Message
CMC
Arguments
Detailed
For failover to occur, the standby CMC needs to be present, at the same version as the primary
Description
and healthy. During failover, the active CMC resets and the standby CMC becomes active. This
message is logged when the standby CMC is absent, unhealthy or at a different firmware
version.
Recommended
Check the status of the standby CMC and make sure the firmware version matches the primary
Response Action
CMC. Then reseat the CMC and retry the operation. If the issue persists, contact your service
provider.
Category
Audit
SubCategory
RDU = Redundancy
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

RDU8506

Message
CMC
Arguments
Detailed
CMC failover is enabled.
Description
Recommended
No response action is required.
Response Action
626
Email
LC Log
Alert
FALSE
TRUE
arg1 cannot go standby since the other CMC is not present or healthy.
arg1 = slot number
Email
LC Log
Alert
FALSE
TRUE
arg1 : enable failover
arg1 = slot number
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
Reset
FALSE
Reset
FALSE