Enc2; Enc3 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Severity
Severity 3 (Informational)
Trap/EventID
4339
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

ENC2

arg1 was removed..
Message
Arguments
Detailed
An Enclosure Management Module (EMM) was removed.
Description
Recommended
Reinsert the Enclosure Management Module (EMM). See the storage hardware documentation
Response Action
for information on replacing the EMM.
Category
Storage
SubCategory
ENC = Storage Enclosr
Severity
Severity 1 (Critical)
Trap/EventID
4337
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

ENC3

arg1 is shutdown.
Message
Arguments
Detailed
The physical disk enclosure is either hotter or cooler than the maximum or minimum allowable
Description
temperature range.
Recommended
Check for factors that may cause overheating or excessive cooling. For example, verify that the
Response Action
enclosure fan is working. You should also check the thermostat settings and examine whether
the enclosure is located near a heat source. Make sure the enclosure has enough ventilation
and that the room temperature is not too hot or too cold. Refer to the enclosure documentation
for more diagnostic information.
212
Email
LC Log
Alert
TRUE
TRUE
arg1 = Enclosure Management Module Name
Email
LC Log
Alert
TRUE
TRUE
arg1 = Enclosure Name
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
Reset
FALSE
Reset
FALSE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents