CMC8512

Message
The Extended Storage feature activation timed out. The feature is not active.
Detailed
The Extended Storage feature is not activated if the removable flash media SD card on the
Description
secondary CMC does not respond within 90 seconds after activation is initiated.
Recommended
Do the following and retry the operation: 1) In the CMC Web interface, go to Chassis Controller
Response Action
> Flash Media > Configuration, and verify if the SD card on secondary CMC displays errors. 2) If
errors are displayed, execute the following racadm command: "racadm cmcchangover". 3)
Repair the removable flash media SD Card by selecting the Chassis Controller > Flash Media >
Configuration > Repair Active Controller Media in the CMC Web interface. Repairing is only
allowed on the SD card of the primary CMC. If the problem persists, replace the card.
Category
Audit
SubCategory
CMC = Chassis Management Controller
Severity
Severity 1 (Critical)
Trap/EventID
8689
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

CMC8513

Message
The Extended Storage feature activation on the secondary CMC timed out. The feature is being
returned to single CMC mode.
Detailed
The Extended Storage feaure activtion on the secondary CMC timed out. If the media on
Description
Standby CMC doesnt respond within 90 seconds of confirming activation the feature returns to
single CMC mode.
Recommended
Do the following and retry the operation: 1) In the CMC Web interface, go to Chassis Controller
Response Action
> Flash Media > Configuration, and verify if the SD card on secondary CMC displays errors. 2) If
errors are displayed, execute the following racadm command: "racadm cmcchangover". 3)
Repair the removable flash media SD Card by selecting the Chassis Controller > Flash Media >
Configuration > Repair Active Controller Media in the CMC Web interface. Repairing is only
allowed on the SD card of the primary CMC. If the problem persists, replace the card.
Category
Audit
SubCategory
CMC = Chassis Management Controller
Severity
Severity 2 (Warning)
Trap/EventID
8690
LCD Message
No LCD message display defined.
Email
LC Log
LCD
Alert
TRUE
TRUE
FALSE
Power Off Power
Reset
Cycle
FALSE
FALSE
FALSE