Bat0008; Bat0009 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Category
System Health
SubCategory
BAT = Battery Event
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
Storage battery has failed. Check battery.
Initial Default.
FALSE
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

BAT0008

Message
The storage battery is present.
Detailed
None
Description
Recommended
No response action is required.
Response Action
Category
System Health
SubCategory
BAT = Battery Event
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
FALSE
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

BAT0009

Message
The storage battery is absent.
Detailed
The PERC RAID controller battery may report absent due to disconnect or thermal exceptions.
Description
Recommended
1) Verify the PERC RAID controller battery installation. 2) If installed, reseat or reconnect the
Response Action
battery and cables. 3) Check the system logs for thermal related issues.
Category
System Health
SubCategory
BAT = Battery Event
Severity
Severity 1 (Critical)
Email
LC Log
LCD
Alert
FALSE
FALSE
FALSE
Email
LC Log
LCD
Alert
FALSE
FALSE
FALSE
Power Off Power
Reset
Cycle
FALSE
FALSE
FALSE
Power Off Power
Reset
Cycle
FALSE
FALSE
FALSE
89

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents