Pwr8582; Pwr8583 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

PWR8582

Message
Chassis Management Controller is unable to turn on server-
Conservation Mode is enabled.
Arguments
Detailed
Unable to turn on the server identified in the message because the Max Power Conservation
Description
Mode (MPCM) is enabled. After MPCM is enabled, the chassis will be in power conservation
mode and the CMC cannot process any further server power on operation requests.
Recommended
Disable the Max Power Conservation Mode and retry the operation.
Response Action
Category
Audit
SubCategory
PWR = Power Usage
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
None
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

PWR8583

Message
Chassis Management Controller is unable to turn on server-
110V PSUs are present.
Arguments
Detailed
To enable 110V operation, the Allow 110VAC Operation feature must be enabled. If the feature
Description
is not enabled, the server turn-on operation will not be processed.
Recommended
On the Power Configuration page, in the Web UI, select the Allow 110VAC Operation for power
Response Action
supplies and retry the operation. Using the RACADM utility, run the following command,
"racadm config -g cfgChassisPower -o cfgChassisAllow110VACOperation 1".
Category
Audit
SubCategory
PWR = Power Usage
Severity
Severity 3 (Informational)
588
Email
LC Log
Alert
FALSE
TRUE
arg1 = slot number
Email
LC Log
Alert
FALSE
FALSE
arg1 = slot number
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
arg1 because Max Power
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
arg1 because unacknowledged
Reset
FALSE
Reset
FALSE

Hide quick links: