Severity
Severity 2 (Warning)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

TMP8502

Message
Able to read planar board temperature sensors. Cooling set for normal chassis operation.
Detailed
The system has recovered from being unable to read planar board or control panel
Description
temperature sensors.
Recommended
No response action required.
Response Action
Category
Audit
SubCategory
TMP = Temperature
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

TMP1000

arg1 exceeded the maximum warning threshold.
Message
Arguments
Detailed
The enclosure is too hot. A variety of factors can cause the excessive temperature. For
Description
example, a fan may have failed, the thermostat may be set too high, or the room temperature
may be too hot.
Recommended
Check for factors that may cause overheating. For example, verify that the enclosure fan is
Response Action
working. You should check the thermostat settings and examine whether the enclosure is
located near a heat source. Make sure the enclosure has enough ventilation and that the room
temperature is not too hot. Refer to the enclosure documentation for more diagnostic
information.
820
Email
LC Log
Alert
FALSE
TRUE
Email
LC Log
Alert
FALSE
TRUE
arg1 = tempsensor name
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
Reset
FALSE
Reset
FALSE