Cmc8547; Cmc8548 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Category
Audit
SubCategory
CMC = Chassis Management Controller
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

CMC8547

Message
Missing kernel module
Arguments
Detailed
A firmware error occurred causing the failover. If this condition continues, a failover will result.
Description
If multiple failovers occur, contact Service.
Recommended
No response action is required. If the issue persists, contact your service provider.
Response Action
Category
Audit
SubCategory
CMC = Chassis Management Controller
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

CMC8548

Message
Unable to communicate with peer CMC.
Detailed
The local CMC has lost network connection with peer CMC for more than the timeout duration.
Description
The timeout duration is 25 seconds for primary CMC and five seconds for secondary CMC.
After detecting the error, failover is performed if secondary CMC is available, otherwise CMC is
reset.
Recommended
Make sure that the network cable is connected to the primary CMC. A Link loss was detected.
Response Action
126
Email
LC Log
Alert
FALSE
TRUE
arg1 . Failover condition detected
arg1 = module name
Email
LC Log
Alert
FALSE
TRUE
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
Reset
FALSE
Reset
FALSE

Hide quick links: