Vdr51; Vdr52 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

VDR51

Message
The consistency check process made corrections and completed on
Arguments
Detailed
The consistency check completed on the virtual disk after making corrections.
Description
Recommended
No response action is required.
Response Action
Category
Storage
SubCategory
VDR = Virtual Disk
Severity
Severity 3 (Informational)
Trap/EventID
4355
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

VDR52

Message
The consistency check found inconsistent parity data on
Arguments
Detailed
The data on physical disk members of the virtual disk does not match. Redundancy may be lost.
Description
Recommended
Rerun the consistency check task. If you receive this message again, verify the health of the
Response Action
physical disks included in the virtual disk. See the storage hardware documentation for more
information. Review messages for significant messages related to the physical disks. If a
physical disk has a problem, replace it and restore from a backup copy. Contact technical
support if the issue persists.
Category
Storage
SubCategory
VDR = Virtual Disk
Severity
Severity 2 (Warning)
884
Email
LC Log
Alert
TRUE
TRUE
arg1 = virtual disk
Email
LC Log
Alert
TRUE
TRUE
arg1 = virtual disk
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
arg1 .
Reset
FALSE
arg1 .
Reset
FALSE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents