Pdr51; Pdr52 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Recommended
Assign a larger disk as the global hot spare.
Response Action
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 2 (Warning)
Trap/EventID
4346
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

PDR51

Message
Hot spare
Arguments
Detailed
The controller firmware attempted to do SMART polling on the hot spare but could not
Description
complete the SMART polling. The controller may have lost communication with the hot spare.
Recommended
Verify the health of the disk assigned as a hot spare. Replace the disk and reassign the hot
Response Action
spare. Make sure the cables are attached securely. See the storage hardware documentation
for more information on checking the cables.
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 1 (Critical)
Trap/EventID
4345
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

PDR52

Message
A redundant path is broken.
Detailed
The controller has two connectors that are connected to the same enclosure. The
Description
communication path on one connector has lost connection with the enclosure. The
communication path on the other connector is reporting this loss.
Email
LC Log
Alert
TRUE
TRUE
arg1 SMART polling has failed. arg2
arg1 = physical disk
arg2 = args
Email
LC Log
Alert
TRUE
TRUE
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
Reset
FALSE
Reset
FALSE
453