Detailed
None
Description
Recommended
No response action is required.
Response Action
Category
System Health
SubCategory
FAN = Fan Event
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
FALSE
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE
FAN0013
arg1 RPM is less than the lower critical threshold.
Message
Arguments
Detailed
The cooling device is not performing optimally. The cooling device may be installed improperly
Description
or may be failing.
Recommended
Remove and re-install the cooling device. If the issue persists, contact technical support. Refer
Response Action
to the product documentation to choose a convenient contact method.
Category
System Health
SubCategory
FAN = Fan Event
Severity
Severity 1 (Critical)
Trap/EventID
2153
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE
FAN0015
Message
arg1 RPM is greater than the upper critical threshold.
Arguments
238
Email
LC Log
Alert
FALSE
FALSE
arg1 = name
•
Email
LC Log
Alert
TRUE
TRUE
arg1 = name
•
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
Reset
FALSE
Reset
FALSE