Cpu0805; Cpu0806 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Recommended
1) Turn system off and remove input power for one minute. Re-apply input power and turn
Response Action
system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact
technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
SubCategory
CPU = Processor
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
Power input for CPU <number> voltage regulator module is outside of range. Reseat module
Initial Default.
FALSE
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

CPU0805

Message
The power input for CPU
the system.
Arguments
Detailed
System performance may be degraded or the system may fail to operate.
Description
Recommended
1) Turn system off and remove input power for one minute. Re-apply input power and turn
Response Action
system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact
technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
SubCategory
CPU = Processor
Severity
Severity 2 (Warning)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
FALSE
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

CPU0806

Message
CPU
Email
LC Log
Alert
FALSE
FALSE
arg1 voltage regulator module is outside of range, but it is attached to
arg1 = number
Email
LC Log
Alert
FALSE
FALSE
arg1 voltage regulator module is incorrectly configure.
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
Reset
FALSE
Reset
FALSE
151