Tmp0132; Tmp0133 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Category
System Health
SubCategory
TMP = Temperature
Severity
Severity 1 (Critical)
Trap/EventID
2161
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

TMP0132

Message
The control panel temperature is greater than the upper warning threshold.
Detailed
Ambient air temperature is too warm or one or more fans may have failed.
Description
Recommended
Check system operating environment and review event log for fan failures.
Response Action
Category
System Health
SubCategory
TMP = Temperature
Severity
Severity 2 (Warning)
Trap/EventID
2162
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

TMP0133

Message
The control panel temperature is greater than the upper critical threshold.
Detailed
Ambient air temperature is too warm or one or more fans may have failed.
Description
Recommended
Check system operating environment and review event log for fan failures.
Response Action
Category
System Health
SubCategory
TMP = Temperature
Severity
Severity 1 (Critical)
Email
LC Log
LCD
Alert
TRUE
TRUE
FALSE
Email
LC Log
LCD
Alert
TRUE
TRUE
FALSE
Power Off Power
Reset
Cycle
FALSE
FALSE
FALSE
Power Off Power
Reset
Cycle
FALSE
FALSE
FALSE
843

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents