Detailed
The bad block table is the table used for remapping bad disk blocks. This table fills as bad disk
Description
blocks are remapped. When the table is full, bad disk blocks are no longer remapped, which
means that disk errors are no longer corrected. At this point, data loss can occur. The bad
block table is now 80 percent full.
Recommended
Replace the disk generating this message.
Response Action
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 2 (Warning)
Trap/EventID
4346
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

PDR57

Message
Bad block table on
Arguments
Detailed
The bad block table is the table used for remapping bad disk blocks. This table fills as bad disk
Description
blocks are remapped. When the table is full, bad disk blocks are no longer remapped, which
means that disk errors are no longer corrected. At this point, data loss can occur.
Recommended
Replace the disk generating this message and restore from a backup copy. You may have lost
Response Action
data.
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 1 (Critical)
Trap/EventID
4345
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE
456
Email
LC Log
Alert
TRUE
TRUE
arg1 is full. Unable to log block arg2 .
arg1 = physical disk
arg2 = logical block address
Email
LC Log
Alert
TRUE
TRUE
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
Reset
FALSE
Reset
FALSE