Pci Event Messages; Pci1300; Pci1302 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

PCI Event Messages

PCI1300

Message
A front panel diagnostic interrupt was detected.
Detailed
The front panel diagnostic was pressed, and the system may be halted as a result. The
Description
interrupt was user induced.
Recommended
Reset the system to continue operation.
Response Action
Category
System Health
SubCategory
PCI = PCI Device
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
FALSE
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

PCI1302

Message
A bus time-out was detected on a component at bus
Arguments
Detailed
System performance may be degraded. The device has failed to respond to a transaction
Description
(master/target abort or completion timeout).
Recommended
Cycle input power, update component drivers, if device is removable, re-install the device.
Response Action
Category
System Health
SubCategory
PCI = PCI Device
Severity
Severity 1 (Critical)
Email
LC Log
Alert
FALSE
FALSE
arg1 = bus
arg2 = device
arg3 = func
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
arg1 device arg2 function arg3 .
24
Reset
FALSE
403

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents