Cpu0001; Cpu0002 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
FALSE
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

CPU0001

Message
CPU
Arguments
Detailed
The processor temperature increased beyond the operational range. Thermal protection shut
Description
down the processor. Factors external to the processor may have induced this exception.
Recommended
Review logs for fan failures, replace failed fans. If no fan failures are detected, check inlet
Response Action
temperature (if available) and reinstall processor heatsink.
Category
System Health
SubCategory
CPU = Processor
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
CPU <number> has a thermal trip. Check CPU heat sink
Initial Default.
FALSE
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

CPU0002

Message
CPU
Arguments
Detailed
None
Description
Recommended
1) Turn system off and remove input power for one minute. Re-apply input power and turn
Response Action
system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact
technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
140
Email
LC Log
Alert
FALSE
FALSE
arg1 has a thermal trip (over-temperature) event.
arg1 = number
Email
LC Log
Alert
FALSE
FALSE
arg1 has failed the built-in self-test (BIST).
arg1 = number
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
Reset
FALSE
Reset
FALSE