Enc19; Enc21 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Detailed
The controller has lost communication with an Enclosure Management Module (EMM). The
Description
cables may be loose or defective.
Recommended
Make sure the cables are attached securely. See the storage hardware documentation for
Response Action
more information on checking the cables. Reboot the system.
Category
Storage
SubCategory
ENC = Storage Enclosr
Severity
Severity 1 (Critical)
Trap/EventID
4337
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

ENC19

arg1 has failed.
Message
Arguments
Detailed
An Enclosure Management Module (EMM) has failed. The failure may be caused by a loss of
Description
power to the EMM. The EMM self-test may also have identified a failure. There may also be a
firmware problem or a multi-bit error.
Recommended
Reseat the Enclosure Management Module (EMM). See the storage hardware documentation
Response Action
for information on replacing the EMM. Replace the EMM. Contact technical support if the issue
persists.
Category
Storage
SubCategory
ENC = Storage Enclosr
Severity
Severity 1 (Critical)
Trap/EventID
4337
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

ENC21

arg1 has been removed.
Message
Email
LC Log
Alert
TRUE
TRUE
arg1 = Enclosure Management Module Name
Email
LC Log
Alert
TRUE
TRUE
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
Reset
FALSE
Reset
FALSE
221

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents