Pdr1101; Pdr1102 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Detailed
The controller detected a drive removal
Description
Recommended
If unintended, verify drive installation. Remove and reseat the indicated disk. If the problem
Response Action
persists, contact technical support. Refer to the product documentation to choose a
convenient contact method.
Category
System Health
SubCategory
PDR = Physical Disk
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
Drive <number> is removed. Check drive
Initial Default.
FALSE
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

PDR1101

Message
Fault detected on drive
Arguments
Detailed
The controller detected a failure on the disk and has taken the disk offline.
Description
Recommended
Remove and reseat the failed disk. If the problem persists, contact technical support. Refer to
Response Action
the product documentation to choose a convenient contact method.
Category
System Health
SubCategory
PDR = Physical Disk
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
Fault detected on drive <number>. Check drive.
Initial Default.
FALSE
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

PDR1102

Message
A predictive failure detected on drive
478
Email
LC Log
Alert
FALSE
FALSE
arg1 .
arg1 = number
Email
LC Log
Alert
FALSE
FALSE
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
arg1 .
Reset
FALSE
Reset
FALSE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents