Pdr98; Pdr100 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 3 (Informational)
Trap/EventID
4347
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

PDR98

Message
Command timeout occurred on
Arguments
Detailed
An error occurred while performing an action on the disk.
Description
Recommended
Check the disk is present or replace the disk.
Response Action
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 2 (Warning)
Trap/EventID
4346
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

PDR100

Message
Dedicated Hot Spare
Arguments
Detailed
The controller is not able to communicate with a disk that is assigned as a dedicated hot spare.
Description
The disk may have been removed. There may also be a bad or loose cable.
Email
LC Log
Alert
TRUE
TRUE
arg1 = physical disk
arg2 = args
Email
LC Log
Alert
TRUE
TRUE
arg1 no longer useful for all arrays.
arg1 = PD Name
LCD
Power Off Power
TRUE
FALSE
arg1 . arg2 .
LCD
Power Off Power
TRUE
FALSE
Reset
Cycle
FALSE
FALSE
Reset
Cycle
FALSE
FALSE
475