Recommended
Turn on the server identified in the message. If the issue persists, contact your service
Response Action
provider.
Category
Audit
SubCategory
PWR = Power Usage
Severity
Severity 2 (Warning)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE
PWR8544
Message
Chassis Management Controller turned off the Server
inventory.
Arguments
Detailed
Insufficient power is available for the server identified in the message to function. The server
Description
will be turned off until there is sufficient power available.
Recommended
Make sure there is enough power supply to distribute power. Using the CMC Web UI, go to
Response Action
Chassis Overview > Power > Power Budget Status. In the Total Input Power Available For
Allocation field view the available power. To add more power, insert more PSUs or remove
unused components from the chassis.
Category
Audit
SubCategory
PWR = Power Usage
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE
PWR8545
Message
Chassis Management Controller turned off the server
retrieved from iDRAC at inventory.
Email
LC Log
Alert
FALSE
TRUE
arg1 = slot number
•
Email
LC Log
Alert
FALSE
TRUE
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
arg1 because of insufficient power at
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
arg1 because of incorrect power data
Reset
FALSE
Reset
FALSE
569