SubCategory
PWR = Power Usage
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE
PWR8573
Message
The Chassis Management Controller is unable to communicate to the iDRAC, when trying to
turn off the server
Arguments
Detailed
The Chassis Management Controller is not able to communicate with the iDRAC on the server
Description
identified in the message. Therefore the server could not be turned off. This situation may
occur when iDRAC is restarting.
Recommended
Wait for three minutes, and then retry the operation. If the issue persists, remove and reinsert
Response Action
the server and wait for the iDRAC to finish restarting before retying the operation.
Category
Audit
SubCategory
PWR = Power Usage
Severity
Severity 2 (Warning)
Trap/EventID
8418
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE
PWR8574
Message
The Chassis Management Controller is unable to communicate to the iDRAC, when trying to
hard reset the server
Arguments
Detailed
The Chassis Management Controller is not able to communicate with the iDRAC on the server
Description
identified in the message. Therefore the server could not be hard reset. This situation may
occur when iDRAC is restarting.
Email
LC Log
Alert
FALSE
TRUE
arg1 .
arg1 = server id
•
Email
LC Log
Alert
TRUE
TRUE
arg1 .
arg1 = slot number
•
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
Reset
FALSE
Reset
FALSE
583