Pwr8573; Pwr8574 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

SubCategory
PWR = Power Usage
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

PWR8573

Message
The Chassis Management Controller is unable to communicate to the iDRAC, when trying to
turn off the server
Arguments
Detailed
The Chassis Management Controller is not able to communicate with the iDRAC on the server
Description
identified in the message. Therefore the server could not be turned off. This situation may
occur when iDRAC is restarting.
Recommended
Wait for three minutes, and then retry the operation. If the issue persists, remove and reinsert
Response Action
the server and wait for the iDRAC to finish restarting before retying the operation.
Category
Audit
SubCategory
PWR = Power Usage
Severity
Severity 2 (Warning)
Trap/EventID
8418
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

PWR8574

Message
The Chassis Management Controller is unable to communicate to the iDRAC, when trying to
hard reset the server
Arguments
Detailed
The Chassis Management Controller is not able to communicate with the iDRAC on the server
Description
identified in the message. Therefore the server could not be hard reset. This situation may
occur when iDRAC is restarting.
Email
LC Log
Alert
FALSE
TRUE
arg1 .
arg1 = server id
Email
LC Log
Alert
TRUE
TRUE
arg1 .
arg1 = slot number
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
Reset
FALSE
Reset
FALSE
583

Hide quick links:

Advertisement

Table of Contents
loading