Stor9; Stor10 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Detailed
High Availability RAID is not supported by this firmware release. This event may occur during
Description
the upgrade process.
Recommended
Remove one RAID controller.
Response Action
Category
Storage
SubCategory
STOR = Storage
Severity
Severity 2 (Warning)
Trap/EventID
4178
LCD Message
No LCD message display defined.
Initial Default.
LCD;#Remote System Log;#None
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

STOR9

Message
No RAID controllers have been detected. Access to shared storage will not be available.
Detailed
No supported RAID controllers have been detected. Access to shared storage will not be
Description
available.
Recommended
Ensure supported RAID controllers are installed.
Response Action
Category
Storage
SubCategory
STOR = Storage
Severity
Severity 2 (Warning)
Trap/EventID
4178
LCD Message
No LCD message display defined.
Initial Default.
LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

STOR10

Message
Access to shared storage will not be available, because the RAID controller is unable to turn
on.
Detailed
The RAID controller was detected, however it is unable to turn on. Access to shared storage
Description
will not be available.
Email
LC Log
LCD
Alert
TRUE
TRUE
TRUE
Email
LC Log
LCD
Alert
TRUE
TRUE
TRUE
Power Off Power
Reset
Cycle
FALSE
FALSE
FALSE
Power Off Power
Reset
Cycle
FALSE
FALSE
FALSE
717