ASR0003

Message
The watchdog timer power cycled the system.
Detailed
The operating system or an application failed to communicate to the baseboard management
Description
controller (BMC). The system powered cycled per the configured setting.
Recommended
Check the operating system, application, hardware, and system event log for exception events.
Response Action
Category
System Health
SubCategory
ASR = Auto Sys Reset
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
FALSE
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

ASR0008

Message
The watchdog timer interrupt was initiated.
Detailed
The operating system or an application failed to communicate to the baseboard management
Description
controller (BMC) within the timeout period. The BMC invoked a system interrupt. (IPMI sensor
type code 23h - offset 00h)
Recommended
Check the operating system, application, hardware, and system event log for exception events.
Response Action
Category
System Health
SubCategory
ASR = Auto Sys Reset
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
FALSE
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE
Email
LC Log
LCD
Alert
FALSE
FALSE
FALSE
Email
LC Log
LCD
Alert
FALSE
FALSE
FALSE
Power Off Power
Reset
Cycle
FALSE
FALSE
FALSE
Power Off Power
Reset
Cycle
FALSE
FALSE
FALSE