Stor5; Stor6 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Severity
Severity 1 (Critical)
Trap/EventID
4177
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

STOR5

Message
Redundancy lost.
Arguments
Detailed
A virtual disk or enclosure has lost data redundancy. In the case of a virtual disk, one or more
Description
physical disks included in the virtual disk have failed. Due to the failed physical disk or disks,
the virtual disk is no longer maintaining redundant (mirrored or parity) data. The failure of an
additional physical disk will result in lost data. In the case of an enclosure, more than one
enclosure component has failed. For example, the enclosure may have suffered the loss of all
fans or all power supplies.
Recommended
Identify and replace the failed components. To identify the failed component, select the
Response Action
Storage object and click the Health subtab. The controller status displayed on the Health
subtab indicates whether a controller has a failed or degraded component. Click the controller
that displays a Warning or Failed status. This action displays the controller Health subtab
which displays the status of the individual controller components. Continue clicking the
components with a Warning or Failed status until you identify the failed component. See
Storage Health for more information. See the enclosure documentation for information on
replacing enclosure components and for other diagnostic information.
Category
Storage
SubCategory
STOR = Storage
Severity
Severity 2 (Warning)
Trap/EventID
4178
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

STOR6

Message
CEM Storage Management detected inventory change(s) after host re-boot.
Email
LC Log
Alert
TRUE
TRUE
arg1
arg1 = VD/Enclosure Name
Email
LC Log
Alert
TRUE
TRUE
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
Reset
FALSE
Reset
FALSE
715

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents