Initial Default.
LC Log
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE
PWR8569
Message
Unable to power cycle the server
Arguments
Detailed
The requested power cycle operation cannot be performed when the server is not turned on.
Description
The server should be already turned on for the power cycle operation to be successful.
Recommended
Turn on the server, if necessary, before requesting a power cycle operation.
Response Action
Category
Audit
SubCategory
PWR = Power Usage
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE
PWR8570
Message
Unable to communicate to the iDRAC, when trying to power cycle the server
Arguments
Detailed
The Chassis Management Controller is not able to communicate with the iDRAC on the server
Description
identified in the message. Therefore, the server could not be power cycled. This situation may
occur when iDRAC is rebooting.
Recommended
Wait for few minutes, and then retry the operation. If the issue persists, do one of the following:
Response Action
1) Reset the iDRAC, 2) Perform a Virtual Reseat of the server, 3) Remove and re-insert the
server.
Category
Audit
SubCategory
PWR = Power Usage
Severity
Severity 2 (Warning)
Email
LC Log
Alert
FALSE
TRUE
arg1 = slot number
•
Email
LC Log
Alert
FALSE
TRUE
arg1 = slot number
•
LCD
Power Off Power
FALSE
FALSE
arg1 because the server is off.
LCD
Power Off Power
FALSE
FALSE
Reset
Cycle
FALSE
FALSE
Reset
Cycle
FALSE
FALSE
arg1 .