Enc4; Enc5 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Category
Storage
SubCategory
ENC = Storage Enclosr
Severity
Severity 1 (Critical)
Trap/EventID
4337
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

ENC4

arg1 firmware mismatch.
Message
Arguments
Detailed
The firmware on the EMM modules is not the same version. It is required that both modules
Description
have the same version of the firmware. This alert may be caused when you attempt to insert an
EMM module that has a different firmware version than an existing module.
Recommended
Download the same version of the firmware to both EMM modules.
Response Action
Category
Storage
SubCategory
ENC = Storage Enclosr
Severity
Severity 2 (Warning)
Trap/EventID
4338
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

ENC5

Message
Redundancy on
Arguments
Detailed
One or more of the enclosure components has failed. For example, a fan or power supply may
Description
have failed. Although the enclosure is currently operational, the failure of additional
components could cause the enclosure to fail.
Email
LC Log
Alert
TRUE
TRUE
arg1 = Enclosure Name
Email
LC Log
Alert
TRUE
TRUE
arg1 is degraded
arg1 = Enclosure Name
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
Reset
FALSE
Reset
FALSE