Vdr31 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Arguments
Detailed
A user changed the write policy for a virtual disk.
Description
Recommended
This alert is provided for informational purposes.
Response Action
Category
Storage
SubCategory
VDR = Virtual Disk
Severity
Severity 3 (Informational)
Trap/EventID
4355
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

VDR31

Message
Controller cache is preserved for missing or offline
Arguments
Detailed
The controller is getting disconnected from its virtual disk, while Input Output (IO) is in-
Description
progress.
Recommended
Try importing foreign disks, if any. Check if the enclosure containing the Virtual Disk is
Response Action
disconnected from the controller. Insert any disks that are reported missing or failed. If the
enclosure or disks were removed intentionally, the preserved cache can be discarded. See
storage hardware documentation for more information on performing these steps.
Category
Storage
SubCategory
VDR = Virtual Disk
Severity
Severity 2 (Warning)
Trap/EventID
4354
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE
arg1 = virtual disk
Email
LC Log
Alert
TRUE
TRUE
arg1 = VD Name
Email
LC Log
Alert
TRUE
TRUE
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
arg1 .
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
Reset
FALSE
Reset
FALSE