Pwr8503; Pwr8504 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

PWR8503

Message
The current value of System Input Power Cap (
Arguments
Detailed
This Information is provided to enable checking whether the powercap is lower than the
Description
maximum supported powercap limit.
Recommended
No response action is required.
Response Action
Category
Audit
SubCategory
PWR = Power Usage
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

PWR8504

Message
Chassis power button is pressed, but the button is disabled.
Detailed
The chassis power button press is detected but the button has been disabled.
Description
Recommended
The chassis power button is disabled. To enable the chassis power button use the CMC
Response Action
RACADM command line interface, CMC Web interface. Using the command line, enter "racadm
config -g cfgChassisPower -o cfgChassisPowerButtonEnable 1". Using the Web interface, click
Chassis Overview > Power > Configuration. Clear the Disable Chassis Power Button check box.
Category
Audit
550
Email
LC Log
Alert
FALSE
TRUE
arg1 = power value
arg2 = power value
Email
LC Log
Alert
FALSE
TRUE
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
arg1 AC) is less than the upper limit ( arg2 AC).
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
Reset
FALSE
Reset
FALSE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents