Cmc8527; Cmc8528 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Detailed
CMC is unable to obtain the CPU information from the server specified in the message. This
Description
occurs if there is no communication between CMC and iDRAC.
Recommended
Do the following: 1) Reset iDRAC. 2) Reset CMC. If the issue persists, contact your service
Response Action
provider.
Category
System Health
SubCategory
CMC = Chassis Management Controller
Severity
Severity 1 (Critical)
Trap/EventID
2545
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

CMC8527

Message
Unable to retrieve the server-
Arguments
Detailed
CMC is unable to obtain the memory information from the server specified in the message. This
Description
occurs if there is no communication between CMC and iDRAC.
Recommended
Do the following: 1) Reset iDRAC. 2) Reset CMC. If the issue persists, contact your service
Response Action
provider.
Category
System Health
SubCategory
CMC = Chassis Management Controller
Severity
Severity 1 (Critical)
Trap/EventID
2545
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

CMC8528

Message
Unable to make a link tuning check for server-
Arguments
118
Email
LC Log
Alert
TRUE
TRUE
arg1 memory information.
arg1 = slot number
Email
LC Log
Alert
TRUE
TRUE
arg1 = slot number
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
arg1 .
Reset
FALSE
Reset
FALSE