Trap/EventID
4346
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

PDR3

arg1 is not functioning correctly.
Message
Arguments
Detailed
The RAID Controller may not be able to read/write data to the physical disk drive indicated in
Description
the message. This may be due to a failure with the physical disk drive or because the physical
disk drive was removed from the system.
Recommended
Remove and re-insert the physical disk drive identified in the message and make sure the
Response Action
physical disk drive is inserted properly. If the issue persists, replace the physical disk drive.
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 1 (Critical)
Trap/EventID
4345
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

PDR4

Message
arg1 returned to a ready state.
Arguments
Detailed
A physical drive that was previously in an error state has returned to a ready state.
Description
Recommended
No response action is required.
Response Action
Category
Storage
428
Email
LC Log
Alert
TRUE
TRUE
arg1 = PD Name
Email
LC Log
Alert
TRUE
TRUE
arg1 = physical disk
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
Reset
FALSE
Reset
FALSE