Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE
PDR88
Message
Power state change failed on
Arguments
Detailed
When physical drives in spun down power state are configured, the drives should transition to
Description
spun up power state.. If the drive is not functioning properly, this transition could fail.
Recommended
Replace the physical disk and try again. Contact technical support if the issue persists.
Response Action
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 1 (Critical)
Trap/EventID
4345
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE
PDR93
Message
Microcode update on
Arguments
Detailed
The physical disk firmware update operation has completed.
Description
Recommended
No response action is required.
Response Action
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 3 (Informational)
472
Email
LC Log
Alert
TRUE
TRUE
arg1 . (from arg2 to arg3 )
arg1 = PD Name
•
arg2 = state
•
arg3 = state
•
Email
LC Log
Alert
TRUE
TRUE
arg1 has completed.
arg1 = physical disk
•
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
Reset
FALSE
Reset
FALSE