Pdr29; Pdr30 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

PDR29

Message
Rebuild on
Arguments
Detailed
See A Rebuild Completes with Errors for more information.
Description
Recommended
See A Rebuild Completes with Errors for more information.
Response Action
Category
Storage
SubCategory
PDR = Physical Disk
Severity
Severity 1 (Critical)
Trap/EventID
4345
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

PDR30

Message
A global hot spare failed.
Arguments
Detailed
The controller cannot to communicate with a disk that is assigned as a global hot spare. The
Description
disk either failed or was removed. There may also be a bad or loose cable.
Recommended
Verify that the disk is healthy and installed. Check the cables. Refer to the product
Response Action
documentation and see the Cables Attached Correctly section for more information on
checking the cables. If necessary, replace the disk and reassign the global hot spare.
Category
Storage
SubCategory
PDR = Physical Disk
442
Email
LC Log
Alert
TRUE
TRUE
arg1 completed with error(s).
arg1 = PD Name
Email
LC Log
Alert
TRUE
TRUE
arg1
arg1 = PD Name
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
Reset
FALSE
Reset
FALSE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents