Enc6 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Recommended
Identify and replace the failed component. To identify the failed component, select the
Response Action
enclosure in the tree view and click the Health subtab. Any failed component will be identified
with a red X on the enclosures Health subtab. Alternatively, you can select the Storage object
and click the Health subtab. The controller status displayed on the Health subtab indicates
whether a controller has a failed or degraded component. See the enclosure documentation
for information on replacing enclosure components and for other diagnostic information.
Category
Storage
SubCategory
ENC = Storage Enclosr
Severity
Severity 2 (Warning)
Trap/EventID
4338
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

ENC6

Message
Communication timeout on
Arguments
Detailed
The controller is unable to communicate with an enclosure. There are several reasons for
Description
communication loss. For example, there may be a bad or loose cable. An unusual amount of I/O
may also interrupt communication with the enclosure. In addition, communication loss may be
caused by software, hardware, or firmware problems, bad or failed power supplies, and
enclosure shutdown.
Recommended
Check for problems with the cables. See the Cables attached correctly section for more
Response Action
information on checking the cables. You should also check to see if the enclosure has
degraded or failed components. To do this, select the enclosure object in the tree view and
click the Health subtab. The Health subtab displays the status of the enclosure components.
Verify that the controller has the supported driver and firmware versions installed and that
each Enclosure Management Modules (EMMs) are running the same version of supported
firmware.
Category
Storage
SubCategory
ENC = Storage Enclosr
Severity
Severity 2 (Warning)
Trap/EventID
4338
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
214
Email
LC Log
Alert
TRUE
TRUE
arg1 .
arg1 = Enclosure Name
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
Reset
FALSE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents