Pwr8527; Pwr8528 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

PWR8527

Message
Server slot power priorities changed - reallocating power.
Detailed
Server slot power priorites were changed. Power to servers is being reallocated.
Description
Recommended
No response action is required.
Response Action
Category
Audit
SubCategory
PWR = Power Usage
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

PWR8528

Message
Unable to set Max Power Conservation Mode because the Server Based Power Management
mode is enabled.
Detailed
The Max Power Conservation Mode can be enabled only when Server Based Power
Description
Management Mode is diabled.
Recommended
The Max Power Conservation Mode can be changed when Server Based Power Management
Response Action
mode is disabled. Using the CMC Web UI, navigate to the Chassis Overview > Power >
Configuration page, then uncheck the Enable Server Based Power Management checkbox.
Retry the operation.
Category
Audit
SubCategory
PWR = Power Usage
Severity
Severity 2 (Warning)
Trap/EventID
FALSE
Email
LC Log
LCD
Alert
FALSE
TRUE
FALSE
Email
LC Log
LCD
Alert
FALSE
TRUE
FALSE
Power Off Power
Reset
Cycle
FALSE
FALSE
FALSE
Power Off Power
Reset
Cycle
FALSE
FALSE
FALSE
561

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents