INVT Goodrive350 Series Operation Manual page 88

Ip55 high-ingress protection vfd
Hide thumbs Also See for Goodrive350 Series:

Advertisement

Goodrive350 IP55 High-ingress Protection Series VFD
Function
code
P01.20
Wake-up-from-sleep delay
P01.21
Restart after power off
Wait time for restart after
P01.22
P01.23
P01.24
Stop speed delay
Open-loop 0Hz output
P01.25
DEC time for emergency
P01.26
Time of starting segment of
P01.27
Time of ending segment of
P01.28
Short-circuit braking
P01.29
Hold time of short-circuit
P01.30
braking for start
Hold time of short-circuit
P01.31
braking for stop
Pre-exciting time for
P01.32
Starting frequency of
P01.33
braking for stop in jogging
P01.34
P05.01–
Digital input function
P05.06
Name
power-off
Start delay
selection
stop
DEC S curve
DEC S curve
current
jogging
Sleep delay
selection
Description
0: Coast to stop
1: Decelerate to stop
0.0–3600.0s (valid only when P01.19 ones
place=2)
0: Disable
1: Enable
0.0–3600.0s (valid when P01.21 is 1)
0.0–60.0s
0.0–100.0s
0: Output without voltage
1: Output with voltage
2: Output with the DC braking current for stop
0.0–60.0s
0.0–50.0s
0.0–50.0s
0.0–150.0% (of the VFD rated Output current)
0.00–50.00s
0.00–50.00s
0–10.000s
0–P00.03
0–3600.0s
1: Run forward
2: Run reversely
4: Jog forward
5: Jog reversely
6: Coast to stop
7: Reset faults
8: Pause running
-70-
Basic operation guidelines
Default
0.0s
0
1.0s
0.0s
0.0s
0
2.0s
0.1s
0.1s
0.0%
0.00s
0.00s
0.300s
0.00Hz
0.0s
See
"Group
P05––
Input
terminal
functions"