Goodrive350 IP55 High-ingress Protection Series VFD
Function
Name
code
P08.25
Set counting value P08.26–65535
Designated
P08.26
counting value
P08.27
Set running time
Auto fault reset
P08.28
count
Auto fault reset
P08.29
interval
Frequency
P08.30
decrease ratio in
droop control
Channel for
switching between
P08.31
motor 1 and motor
FDT1 electrical
P08.32
level detection
3: Three
0–P08.25
0–65535min
Auto fault reset count: When the VFD uses
automatic fault reset, it is used to set the
number of automatic fault reset times. When
the number of continuous reset times exceeds
the value, the VFD reports a fault and stops.
Auto fault reset interval: Time interval from
when a fault occurred to when automatic fault
reset takes effect.
After VFD starts, If no fault occurred within 600s
after the VFD starts, the number of automatic
fault reset times is cleared.
Setting range of P08.28: 0–10
Setting range of P08.29: 0.1–3600.0s
The output frequency of the VFD changes as
the load changes. The function code is mainly
used to balance the power when several motors
drive a same load.
Setting range: 0.00–50.00Hz
0x00–0x14
Ones place: Switchover channel
0: Terminal
1: Modbus/Modbus TCP communication
2: PROFIBUS/CANopen/DeviceNet
communication
3: Ethernet communication
4: EtherCAT/PROFINET/ EtherNet IP
2
communication
Tens place: indicates whether to enable
switchover during running
0: Disable
1: Enable
When the output frequency exceeds the
corresponding frequency of FDT electrical level,
Description
-175-
Function parameter list
Default Modify
0
0
0min
0
1.0s
0.00Hz
0x00
50.00Hz