Group P92––Tension control optimization functions
Function
Name
code
Pre-drive speed
P92.00
gain
Pre-drive torque
P92.01
limit
Pre-drive torque
P92.02
limit setting
Zero bit conversion
P92.03
enabling
P92.04
Initial zero bit
P92.05
Final zero bit
Conversion time
P92.06
from initial zero bit
to final zero bit
Conversion time
P92.07
from final zero bit to
initial zero bit
Feeding interrupt
P92.08
detection mode
Feeding interrupt
P92.09
detection start
delay time
Frequency lower
P92.10
limit of feeding
interrupt detection
Error range of
P92.11
feeding interrupt
detection
Determination
P92.12
delay time of
Description
0.0–100.0%
0–2
0: Set based on P03.20, P03.21
1: Set based on P93.02
2: Set based on the set tension
0.0–200.0%
0–1
0: Disable
1: Enable
0.0–100.0%
0.0–100.0%
0.00–60.00s
0.00–60.00s
0–3
0: No detection
1: Detect based on digital value
2: Detect based on roll diameter calculation
value
3: Detect based on feedback position
0.0–200.0s
0.00–300.00Hz
0.1–50.0%
0.1–60.0s
-262-
Function parameter list
Default Modify
100.0%
2
100.0%
0
10.0%
50.0%
5.00s
5.00s
0
20.0s
10.00Hz
10.0%
1.0s