Download Print this page

INVT Goodrive350 Series Operation Manual page 276

Ip55 high-ingress protection vfd
Hide thumbs Also See for Goodrive350 Series:

Advertisement

Goodrive350 IP55 High-ingress Protection Series VFD
Function
Name
code
Tension PID output
P90.28
reference
Tension PID
P90.29
parameter source
Group 1
P90.30
proportional gain
Group 1 integral
P90.31
time
Group 1 differential
P90.32
time
Group 2
P90.33
proportional gain
Group 2 integral
P90.34
time
Group 2 differential
P90.35
time
PID parameter
P90.36
adjustment
reference point 1
PID parameter
P90.37
adjustment
reference point 2
Min. frequency for
P90.38
roll diameter
calculation
Min. linear speed
P90.39
for roll diameter
calculation
Description
0: Remain current roll diameter
1: Restore to initial roll diameter
Thousands place: Terminal reset limitation
0: Reset allowed at running
1: Reset only allowed at stop
0: Maximum value
1: Given value
0: First group of P90
1: Roll diameter (max. roll diameter)
2: Main reference frequency (max. Frequency)
3: Running linear speed (max. linear speed)
4: Deviation (Reference 100%)
5: Terminal
0.000–30.000
0.00–30.00s
0.00–10.00s
0.000–30.000
0.00–30.00s
0.00–10.00s
0.0–P90.37%
P90.36–100.0%
0.00–50.00Hz
Note: Valid only for linear speed calculation
with roll diameter.
0.0–100.0%
Note: Relative to the max. linear speed.
Note: Valid only for linear speed calculation
with roll diameter.
-258-
Function parameter list
Default Modify
0
0
0.030
5.00s
0.00s
0.030
5.00s
0.00s
10.0%
50.0%
0.30Hz
3.0%