Goodrive350 IP55 High-ingress Protection Series VFD
Setting
Function
Switch between A setting
13
and B setting
Switch between
combination setting and A
14
Switch between
combination setting and B
15
16
Multi-step speed terminal 1 A total of 16-step speeds can be set by combining digital
17
Multi-step speed terminal 2
18
Multi-step speed terminal 3
19
Multi-step speed terminal 4
Pause multi-step speed
20
21
ACC/DEC time selection 1 The status of the two terminals can be combined to select
22
ACC/DEC time selection 2
23
Simple PLC stop reset
24
Pause simple PLC
25
Pause PID control
Pause wobbling frequency
26
(stop at current frequency)
Reset wobbling frequency
27
(back to center frequency)
setting can clear the frequency value of auxiliary channel
set by UP/DOWN, thus restoring the reference frequency to
the frequency given by main reference frequency command
channel.
The function is used to switch between the frequency
setting channels.
A frequency reference channel and B frequency reference
channel can be switched by function 13; the combination
setting
channel set by P00.09 and the A frequency reference
channel can be switched by function 14; the combination
channel set by P00.09 and the B frequency reference
channel can be switched by function 15.
setting
states of these four terminals.
Note: Multi-step speed 1 is the low-order bit, and multi-step
speed 4 is the high-order bit.
The multi-step speed selection function can be screened to
running
keep the set value in the present state.
four groups of ACC/DEC time.
Used to clear the previous PLC state memory information
and restart the simple PLC process.
Used to pause the simple PLC. When the function is
revoked, the simple PLC resumes the running.
PID is ineffective temporarily, and the VFD maintains
current frequency output.
The VFD pauses at current output. After this function is
canceled, it continues wobbling-frequency operation at
current frequency.
The set frequency of VFD reverts to center frequency.
Description
Multi-step
Multi-step
speed 4
speed 3
Bit3
Bit2
T1
T2
ACC/DEC time
OFF
OFF
ACC/DEC time 1
ON
OFF
ACC/DEC time 2
OFF
ON
ACC/DEC time 3
ON
ON
ACC/DEC time 4
-84-
Basic operation guidelines
Multi-step
Multi-step
speed 2
speed 1
Bit1
Bit0
Parameter
P00.11/P00.12
P08.00/P08.01
P08.02/P08.03
P08.04/P08.05

Advertisement