Goodrive350 IP55 High-ingress Protection Series VFD
Function
Name
code
P10.37 Multi-step time unit
Group P11––Protection parameters
Function
Name
code
Protection against
P11.00
phase loss
Frequency drop at
P11.01
transient power-off
Enabling dynamic
P11.02
braking in standby
mode
Overvoltage stall
P11.03
protection
Description
automatically
after
running at the frequency defined by this step in
the remaining time.
0: second
The running time of each step is counted in
seconds.
1: minute
The running time of each step is counted in
minutes.
Description
0x000–0x111
Ones place:
0: Disable software input phase loss protection.
1: Enable software input phase loss protection.
Tens place:
0: Disable protection against output phase loss.
1: Enable protection against output phase loss.
Hundreds place:
0: Disable hardware input phase loss
protection.
1: Enable hardware input phase loss protection.
0: Disable
1: Enable
0: Enable
1: Disable
0: Disable
1: Enable
DC bus voltage V
Overvoltage stall
threshold
Output
frequency
-189-
restart,
then
continue
Time t
Time t
Function parameter list
Default Modify
0
Default Modify
0x110
0
0
1